Master the data-driven framework required under EECA 2024. Turn raw energy data into audit-ready baseline models, defensible savings proof, and compliance reporting for Registered Energy Managers (REM).
"You cannot manage what you cannot baseline. Baseline regression separates real savings from operational noise."
8 Hours
CDP Points / Hours
21,600 GJ
EECA 2024 Threshold
≥ 12 Mos
Baseline Data Required
R² ≥ 0.75
Target Statistical Validity
0.0036 GJ
Conversion per kWh
Structured competency building across key energy management pillars.
Grasp concepts of energy baselines, EnPI/EEI (SEC/BEI), and variables affecting electrical and thermal energy use.
Compile ≥12 months data, establish baseline, normalize weather/production data, and convert metrics to GJ.
Perform linear & polynomial regression analysis in Excel to model energy consumption and identify key drivers.
Interpret statistical outputs, detect performance anomalies, and isolate Significant Energy Uses (SEUs).
Validate model robustness, set performance targets, and track normalized savings under EnMS & Act reporting.
Under the Energy Efficiency & Conservation Act 2024 (gazetted Dec 31, 2024; enacted Jan 1, 2025), commercial and industrial facilities consuming ≥21,600 GJ over 12 consecutive months must fulfill mandatory corporate directives.
Type 1 or Type 2 dependent on consumption thresholds (21,600 GJ to >50,000 GJ).
Framework setup within 1 year of REM appointment.
Electronic reporting within 30 days of REM 1-year anniversary.
Maintain minimum 2-Star performance standard for office buildings with GFA ≥ 8,000 m².
| Energy Resource | Conversion Coefficient |
|---|---|
| Electricity | 0.0036 GJ / kWh |
| Solar Photovoltaic | 0.0036 GJ / kWh |
| Natural Gas | 0.045544 GJ / kg |
| Steam (10 bar) | 2.78 GJ / tonne |
| Chilled Water | 0.01266 GJ / RTh |
6 structured modules designed for Energy Managers, Engineers, and Auditors.
Legal structure, compliance timelines, Energy Consumer thresholds, and Building Energy Intensity (EI) labeling.
Establishing reference levels over 12+ months, baseline adjustments, and handling static vs. variable factors.
Setting up EACs across facilities, defining Specific Energy Indicators (SEI/BEI), and unit benchmarking.
Dependent vs. independent variables, weather degree days (CDD via DegreeDays.net), sub-metering, and sampling.
Extracting utility bill data, understanding tariff structures (Tariff C2, E2), maximum demand, and connected load charges.
Linear/Polynomial modeling in Excel Analysis ToolPak, outlier removal (IQR), R²/RMSE validation, and ESM savings reporting.
Learn Directly From Certified Experts and Senior Academic Researchers.
Energy Specialist focusing on energy audit, IPMVP implementation, and sustainability project verification.
Certified M&V Professional (CMVP) with extensive industry experience in energy management and efficiency projects.
All prices are inclusive of SST at 8% • Inclusive of 8 CDP Hours Certificate